Volume
50L ~ 20000L
-
Height to diameter ratio
Customize according to customer needs
-
Cultivate objects
CHO cells
-
Cleaning/sterilization method
In-place CIP/SIP
-
Tank material
Stainless steel 316L Ra<0.4um EP
-
Stirring
Magnetic stirring is installed at the bottom; 2-layer elephant ear or pitched blade blades; the height of the blades can be adjusted, and the assembly method is no dead angle assembly;
-
Intake and exhaust
The sterile filter with a stainless steel shell is equipped with a vent pipe and a gas distributor, and the maximum ventilation volume can reach 2wm
-
Temperature control
The closed-cycle TCU system adopts indirect heat exchange between steam and cooling water, and achieves precise temperature control and air elimination through cascade PID.
-
pH
Using smart PH electrode; associated control with alkali supplementation and CO2;
-
Dissolved oxygen
Use smart, optical DO electrode; associated control with stirring, ventilation, and oxygen;
-
Defoaming
Associated control of the defoamer supplement pump and defoamer electrode, automatic defoaming; provide timely and quantitative defoamer supplement program;
-
Supplement
Provide customized replenishment strategy;
-
Control system
Provide PLC and PCS7 two automatic control system architectures
-
Extended functions
Reserved digital and analog input/output interfaces (no setting), which can be connected to external equipment (such as balance, turbidity, etc.)
-
Optional
Viable cell count detection; online exhaust gas analysis; weighing\liquid level monitoring; refill balance measurement